Welcome to
Sysmex Flow Cytometry France!

For ordering please make sure you are in your local shop.
If you are from France then please continue.
Otherwise please go to your country.

Go to my country Continue

CyFlow™ CD34 Alexa Fluor™ 700

CyFlow™ CD34 Alexa Fluor™ 700
Antigen: CD34
Clone: 4H11[APG]
Application: Flow cytometry
Format/Fluorochrome: Alexa Fluor™ 700
Laser: Red
Target Species: Human
Field of Interest: Immunophenotyping
Species of Origin: Mouse
Regulatory Status: RUO
Clonality: monoclonal
Emission Maximum: 723 nm
Excitation Maximum: 702 nm
Isotype: IgG1
Order number: CM816954

For Research Use Only
Not for use in diagnostic or therapeutic procedures.

Quantity 100 tests Volume 0.4 ml Immunogen Permanent human cell line derived from... more
CyFlow™ CD34 Alexa Fluor™ 700
Quantity100 tests
Volume0.4 ml
ImmunogenPermanent human cell line derived from peripheral leucocytes of a patient suffering from chronic myeloid leukaemia
SpecifityThe mouse monoclonal antibody 4H11[APG] recognizes Class III epitope on CD34 antigen, a 110-115 kDa monomeric transmembrane phosphoglycoprotein expressed on hematopoietic progenitors cells and on the most pluripotential stem cells; it is gradually lost on progenitor cells. The antibody 4H11[APG] completely blocks binding of Class II antibody QBEnd10 and Class III antibodies BIRMA K3 and 8G12 on KG1a cell line.
Background InformationCD34 (Mucosialin) is a highly glycosylated monomeric 111-115 kDa surface protein, which is present on many stem cell populations. It is a well established stem cell marker, though its expression on human hematopoietic stem cells is reversible. CD34 probably serves as a surface receptor that undergoes receptor-mediated endocytosis and regulates adhesion, differentiation and proliferation of hematopoietic stem cells and other progenitors. CD34 expression is likely to represent a specific state of hematopoietic development that may have altered adhering properties with expanding and differentiating capabilities in both in vitro and in vivo conditions.
UsageThe reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 4·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests.
Storage BufferThe reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.1% (w/v) sodium azide.
StorageAvoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
StabilityDo not use after expiration date stamped on vial label.

Article successfully added.